Monogram refrigeration error code

Monogram Refrigerator CC: Compressor Control Check Failed

CC on a Monogram refrigerator means the compressor control circuit failed its own self-check. The board then stops telling the compressor to run.

Needs attention soonChecked November 2026

What does Monogram refrigeration code CC mean?

CC tells you the circuit that controls the compressor in your Monogram refrigerator failed its own self-check, which is a wider problem than the compressor alone. The board stopped sending the run command because it could not confirm the circuit was working normally. Three things could be behind it: the compressor start relay or capacitor, the compressor windings, which may have shorted or opened, or the output stage on the main control board. Each one has to be tested in turn before the failed part is known.

CC at a glance

Code
CC
Appliance
Monogram refrigeration
Applies to
Monogram refrigerator columns with a compressor-control check
Type
Needs attention soon
Can you clear it yourself?
Sometimes, after the safe checks below
Most likely cause
The compressor start relay or capacitor has failed

What you may notice with CC

  • CC appears on the refrigerator display
  • The compressor does not start or run
  • The cabinet gets warmer as hours pass
  • Lights and the display may still work

How the refrigeration detects CC

In a Monogram refrigerator, the compressor is driven through a circuit with a start relay, a capacitor, and an output stage on the main control board. When cooling is needed, the board sends the command and the circuit starts the compressor turning.

The board also runs a self-check on that circuit. If it cannot confirm that the circuit is behaving normally, it stops commanding the compressor and shows CC. This is a protective step, since driving a compressor through a circuit that is not working right could damage it further. The result is that cooling stops, even though lights and the display may stay on. The failure could be the relay or capacitor, windings that have shorted or opened, or the board output stage. Each one is checked in turn, and some steps need the unit powered.

Likely causes of CC

  • The compressor start relay or capacitor has failed
  • The compressor windings have shorted or opened
  • The main control board output stage has failed

Can you keep using the refrigeration with CC?

You can leave the refrigerator plugged in while you wait for service, but it will not cool without the compressor. The cabinet warms over time. Read the compartments with a thermometer and pack perishable food into iced coolers if they climb. If you smell burning or hear a loud buzz from the lower area, switch the unit off at the breaker.

What you can safely check

  1. Shut off power at the breaker or unplug the unit, and do not open any lower or rear panel.
  2. Keep the lower grille clear and make sure nothing blocks the vents around the cabinet.
  3. Restore power and listen for the compressor to start, then check whether CC returns.
  4. Place a thermometer in each compartment to see how fast it warms. The compressor circuit is high current and high voltage, so no owner testing is safe. If CC stays on, call us.

What our technician does for CC

  • Test the start relay and capacitor with the unit opened and partly de-energized
  • Test the compressor windings for a short or an open circuit
  • Check the output stage of the main control board

How to keep CC from coming back

  • Keep the lower grille and vents clear so the compressor compartment can shed heat
  • Use a surge protector, since Florida storms can send surges that stress the compressor circuit
  • Do not let the refrigerator sit in a hot, closed-in space, where the sealed system works harder

Technical reference

Code
CC
Appliance
Monogram refrigeration
Control family
Monogram refrigerator columns with a compressor-control check
Checked
November 2026

Code meanings come from the maker’s documentation and our own repair work; we do not reprint the maker’s document. Confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Haier US Appliance Solutions, Inc..

FAQ

CC questions

Is CC a compressor failure?

Not necessarily. CC says the compressor control circuit failed a self-check, which includes the relay, the capacitor, the windings, and the board output. Any one of them can trigger it.

Why does the technician need to pull the unit out?

On a built-in column, getting to the compressor compartment typically means sliding the unit partway out of the cabinetry. That gives safe access to the parts that need testing.

Can I save my food while CC is showing?

Yes, if you act quickly. The compressor is stopped, so the cabinet will warm. Use a thermometer, move perishable food to a cooler with ice, and follow the USDA and FDA guidance.

Will CC go away after a reset?

A restart may clear the message for a short time, but if the relay, capacitor, windings, or board output has failed, the board will find the problem again and CC will return.

What happens if I ignore CC?

The compressor stays stopped, so the cabinet keeps warming and food is at risk. The sooner the failed part is found, the less food you stand to lose.

Need help with CC?

We trace the cause in your home first and write the price down before any part is swapped.

Call Book a Repair
Call (813)750-0388 Book a Repair