Monogram Rangetop E3: Gas Valve Not Confirming Closed
E3 on a Monogram rangetop means a burner knob was turned to off but the control system is not confirming that the gas valve actually closed. It is a genuine safety problem.
What does Monogram rangetop code E3 mean?
With E3, you have turned a burner knob to the off position, but the rangetop's control system never gets confirmation that the matching gas valve shut. This is a safety problem rather than a convenience glitch, because a valve that stays open lets gas keep flowing to the burner. The cause may be a gas valve solenoid that has failed in the open position, or a failure in the circuit that controls the valve. Do not use the rangetop until a technician confirms the valve closes.
E3 at a glance
- Code
- E3
- Appliance
- Monogram rangetop
- Applies to
- Monogram gas rangetop burner controls
- Type
- Needs attention soon
- Can you clear it yourself?
- Sometimes, after the safe checks below
- Most likely cause
- A gas valve solenoid stuck in the open position
What you may notice with E3
- E3 appears right after a burner knob goes to off
- The burner looks off while the code stays on the display
- Any gas smell near the rangetop means leave the home immediately
How the rangetop detects E3
When you turn a burner knob on a Monogram rangetop, the control system opens that burner's gas valve. Turn the knob back to off, and the system expects the valve to close and report back that it did. That confirmation is a safety step, because gas should stop reaching a burner the moment the knob says off.
E3 is raised when the confirmation never arrives. Either the valve solenoid has stuck in the open position, or the circuit that commands and monitors the valve has stopped working. The control cannot tell which, so it treats the situation as unsafe and reports the code. Since a valve that does not shut leaves gas available at the burner, this is handled as a safety matter and not as a cosmetic display problem.
Likely causes of E3
- A gas valve solenoid stuck in the open position
- A failure in the circuit that controls the valve
Can you keep using the rangetop with E3?
Do not use the rangetop with E3 active. A gas valve that will not confirm closing is a safety problem, and the burner could still be receiving gas even though the knob is off. Shut the gas off at the rangetop's shutoff valve if you can reach it safely, and leave the home at once if you ever smell gas.
What you can safely check
- Make sure every knob is at off. If you smell gas, leave the home now, do not touch switches or phones inside, and call the gas utility or 911 from outside.
- With no gas smell, and only if you can reach the shutoff valve safely, turn the gas supply to the rangetop off at that valve.
- Switch off the rangetop's breaker.
- Do not use the rangetop again until a technician has confirmed the valve closes, and call us.
What our technician does for E3
- Test whether the gas valve closes when the knob is turned off
- Test the valve solenoid and replace the valve if it fails to close
- Check the valve control circuit and the board output that drives it
How to keep E3 from coming back
- Know where the rangetop's gas shutoff valve is and keep it reachable so you can close it quickly.
- Turn knobs fully to off after cooking and look at the burners before leaving the kitchen.
- Report any gas smell, even a faint one, right away instead of waiting for a code to appear.
Technical reference
- Code
- E3
- Appliance
- Monogram rangetop
- Control family
- Monogram gas rangetop burner controls
- Maker documentation
- Monogram owner manuals and support
- Checked
- November 2026
Code meanings come from the maker’s documentation and our own repair work; we do not reprint the maker’s document. Confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Haier US Appliance Solutions, Inc..
Related Monogram rangetop error codes
E3 questions
Is E3 an emergency?
Treat it as a serious safety problem. If you smell gas, leave the home and call the gas utility or 911 from outside. With no smell, shut the gas at the rangetop valve and stop using the unit until it is checked.
Can I fix an E3 gas valve myself?
No. Work on a gas valve is never a do-it-yourself repair, because a mistake can leave gas flowing. Shutting off the supply and switching off power are the only owner steps.
Why does E3 appear after I turned the knob off?
The control watches the valve after each knob change. When it does not see the valve confirm closing, it raises E3 even though the knob itself sits in the off position.
What details about E3 matter most to the technician?
Tell them which burner knob you turned off when E3 appeared, whether you smelled gas, and whether you closed the shutoff valve. These details help them go straight to the valve and its control circuit.
Can E3 be a false alarm?
The code means the control did not see the valve confirm closing, and that can come from a failed solenoid or a failed control circuit. Because either one matters for safety, treat it as real until a technician has tested the valve.
Need help with E3?
We trace the cause in your home first and write the price down before any part is swapped.